The 'Service' function control a timer ('No-Action Timer') which starts as soon as no action in the house is detected. When the timer has expired, an alarm ('No-Action Alarm) is activated.

Parameters

Within the function

The parameters for the Service functions are set in the PROSOFT 'option' menu. Under the tab page 'Option', you will find in the 'Service field' following parameters:
Image194

No-Action Timer
This parameter sets the duration before the 'No-Action Alarm' is activated. The 'No action Timer' is adjustable per 15 min from 00h 00min till 48h 00min. By default the time is set at 10h00min.
No Action Alarm
Select here the function which has to be activated when during the 'No-Action Timer' no movement was recorded. Following functions can be selected: 'Switch', 'Local Mood', 'Timed Local Mood', 'General Mood' and 'Process Functions'. Depending on the selected function some function specific parameters are necessary. Consult for this matter the description of the selected function.

Operation from another interface

'No-Action Control ON/OFF' type

Short
With a short push on the button the 'No-Action Control' is switched on when the function was 'OFF'. When the function is 'ON', the function is switched off. The 'No-Action Control' activates the 'No-Action Timer'.
Long
The operation is the same as described under 'Short'.

'No-Action Reset Timer' type

Short
With a short push on the button the 'No-Action Timer' is set back to the preset time. The timer starts running again from the beginning.
Long
The operation is the same as described under 'Short'.
When the 'No-Action Timer' was not started by the 'No-Action Control ON/OFF', then the 'No-Action Reset Timer' will have no implications.

Operation in another function

'No-Action Control ON/OFF' type

Depending on the preset target value the 'No-Action Control ON/OFF' will be controlled as follows:

On
When the other function is switched on the 'No-Action Control ON/OFF' will be switched on: the 'No-Action Timer' starts.
Off
When the other function is switched on the 'No-Action Control ON/OFF' will be switched off: the 'No Action Timer' stops.
On/Off
When the other function is switched on the 'No-Action Control ON/OFF' will be switched on. When the other function is switched off the 'No-Action Control ON/OFF' will be switched off.
Off/Off
When the other function is switched on the 'No-Action Control ON/OFF' will be switched off. When the other function is switched off the 'No-Action Control ON/OFF' will be switched off.

'No-Action Reset Timer' type

With the 'No-Action Reset Timer' the target value is not adjustable. For information purposes the target value is indicated in pale grey. Following target values are visible:

Reset
When the other function is activated the 'No Action Timer' is set again at the initially introduced starting time. Said differently the actively running timer is deleted.
Reset/Reset
When the other function is activated and as well when it is switched off the 'No Action Timer' is set again at the initially introduced starting time. Said differently the actively running timer is deleted.
Not every function can be switched off. Consult the description of the respective function.