Table of contents: Introduction PROSOFT The basic flow diagram of a configuration session The full flow diagram Starting up a new project Collecting the project information Starting a project TELETASK CLOUD installation Remote connections Use of passwords and codes The rooms 'O' Units: Outputs Adding Output units Assigning TELETASK Outputs List of output units of your project TDS13530 Fan coil unit interface TDS13609: Dimmer interface 8x 0-10V TDS13611: Fluorescent Dimmer Interface TDS13621: DALI - DSI - DMX interface TDS13632 and TDS13634: PWM LED Dimmers TDS13642 and TDS13644: Universal power FET Dimmer 'I' units: Inputs and others TDS12340BE P1 INTERFACE FOR DIGITAL METER TDS12070: OPUS The alarm- icon on the opus mainscreen Intercom on OPUS Video Door Phone Compatibility Tests Siedle Fasttel Comelit 2N DIVUS CAME BPT DoorBird FERMAX TDS10119V2 and Camera server Adding TELETASK 'I' interfaces General 'I' interfaces – Specific parameters Advanced settings for AURUS touch panels TDS12025 AURUS-2 SENSE TDS12022 AURUS-OLED and TDS12032 AURUS-OLED PLUS TDS12064 AURUS-TFT Digital Input interfaces – Specific parameters Analogue input interface – Specific parameters Audio Interfaces – Specific parameters Overview list of 'I' Interfaces of your domotics project TDS12117 Digital Input interface with Pulse counter sensor TDS14061 HVAC Modbus Master interface TDS14065 : IR-COOKIE INTERFACE TDS15200 Airco Software license TDS20065 Universal HVAC TDS20067xx and TDS20068 HVAC PLUG and HUB Extra Parameters for External HVAC systems Functions overview The Relay functions The Dimmer functions Working with motors The FAN function The Fan functions The Timed functions The Motion detector function Constant Lighting Control The Sensor Functions The Fan (exhaust) function The Local Mood function The Timed Local Mood function The General Mood function The Transparent function The Messages and Alarms functions Send SMS with intellisoftware The TP Buzzer functions The 'If-Then-Else' function The Process functions The 'Flag' function The Condition Calculation function The Service functions The clock functions The audio functions Send IR, RS232 OR IP Code The Auto start function The Display Functions Touch screen functions The step function The RGB function The tunable white function Astro clock function for Astronomic based actions Communication Connecting your PC with the central unit Connection trouble shooting Communication with the DOIP central unit Overview of your domotic project Diagnostics Relays Dimmers Motors Digital Inputs Analogue Inputs Audio Zones Other Functions Interfaces Monitor CARDSOFT – PORTA Steps to set up CARDSOFT-PORTA Access control options in PROSOFT Add Proximity readers Create Users and Groups Define ‘Access rights’ Access management on users and groups Schedule E-mail reports with TIMESOFT (or a function) TIMESOFT Actions based on time programs Defining a clock action GUISOFT Personalised graphical control Glossary System Requirements Schematic Configurations GUISOFT Licence Making a GUI Requirements Session workflow CREATING A GUI GUI Selection GUI Properties GUISOFT Screen Adding items to the GUI Creating a iSGUI Start with the GUISOFT ATMOS - iSGUI Selection ATMOS Features GUISOFT Screen (ATMOS - iSGUI) Adding items to the iSGUI and ATMOS Creating a Control Tower Terminology Workflow Define Functions to monitor and control Create an initial PROSOFT file Create a Control Tower configuration Event logs (alarms) Get the GUI ready for use Video door phone, Intercom on GUI and MAIOR Video door phone on GUI (TDS12052 and TDS12053 only) AV-SOFT Audio-IP software licence Multi-Room Multi-Source Multi-room/Multi-source: the differences Phase 1: Choose the wanted audio-video configuration Phase 2: Assigning the RS232 Port and the IR flashers Phase 3: Configuring the Universal RS232 AV or IP interface Phase 4: Configuring the audio buttons of the domotics installation Edit library Add and edit devices into the library Record IR codes Paste IR codes RS232, IP Polling codes Special codes BACK-UP the AV-SOFT Library Connection to the RS232 UNIVERSAL AV INTERFACE RS232 connection Splitter Cable for audio system DALISOFT VOICESOFT Amazon Alexa Voice Cotrol Configuration of Amazon Alexa Voice Control Google Home Voice Control Configuration of Google Home Voice Control Application examples and technical cases How to integrate IP camera’s with TDS How to integrate streaming audio devices HEOS integration Sonos integration Bose integration How to integrate a heating and cooling system How to integrate a light sensor How to setup an access control system Configuring a NUVO installation with three RS interfaces B&O Integration Implementing NuVo with Audio IP License (TDS15240) Configuring Audio Systems With the Audio IP License TDS15240 Program a TCP client for third party system on port 23 Night cooling Multiple DoIP Central Units Energy management TTecomm The TTecomm platform TSF Services Handbook The ATMOS TSF Subscription Q&A Questions and Answers How to integrate a Daikin unit with standard ON-OFF control How to detect whether your Power Supply load is 70% What is full galvanic isolation Can you use one AUTOBUS power supply for AUTOBUS 1 AND 2 in a NANOS installation How can you know that there is a voltage drop on AUTOBUS cable What is AUTOBUS terminator and how does it work Multiple installations TTcloud account policy Calculate the power loss and heat generation of an electrical distribution board On iSGUI, I keep getting an hourglass on some items TELETASK Technical handbookIntroductionPROSOFTThe basic flow diagram of a configuration sessionThe full flow diagramStarting up a new projectCollecting the project informationStarting a projectTELETASK CLOUD installationRemote connectionsUse of passwords and codesThe rooms'O' Units: OutputsAdding Output unitsAssigning TELETASK OutputsList of output units of your projectTDS13530 Fan coil unit interfaceTDS13609: Dimmer interface 8x 0-10VTDS13611: Fluorescent Dimmer InterfaceTDS13621: DALI - DSI - DMX interfaceTDS13632 and TDS13634: PWM LED DimmersTDS13642 and TDS13644: Universal power FET Dimmer'I' units: Inputs and othersTDS12340BE P1 INTERFACE FOR DIGITAL METERTDS12070: OPUSThe alarm- icon on the opus mainscreenIntercom on OPUSVideo Door Phone Compatibility TestsSiedleFasttelComelit2NDIVUSCAME BPTDoorBirdFERMAXTDS10119V2 and Camera serverAdding TELETASK 'I' interfacesGeneral 'I' interfaces – Specific parametersAdvanced settings for AURUS touch panelsTDS12025 AURUS-2 SENSETDS12022 AURUS-OLED and TDS12032 AURUS-OLED PLUSTDS12064 AURUS-TFTDigital Input interfaces – Specific parametersAnalogue input interface – Specific parametersAudio Interfaces – Specific parametersOverview list of 'I' Interfaces of your domotics projectTDS12117 Digital Input interface with Pulse counter sensorTDS14061 HVAC Modbus Master interfaceTDS14065 : IR-COOKIE INTERFACETDS15200 Airco Software licenseTDS20065 Universal HVACTDS20067xx and TDS20068 HVAC PLUG and HUBExtra Parameters for External HVAC systemsFunctions overviewThe Relay functionsThe Dimmer functionsWorking with motorsThe FAN functionThe Fan functionsThe Timed functionsThe Motion detector functionConstant Lighting ControlThe Sensor FunctionsThe Fan (exhaust) functionThe Local Mood functionThe Timed Local Mood functionThe General Mood functionThe Transparent functionThe Messages and Alarms functionsSend SMS with intellisoftwareThe TP Buzzer functionsThe 'If-Then-Else' functionThe Process functionsThe 'Flag' functionThe ConditionCalculation functionThe Service functionsThe clock functionsThe audio functionsSend IR, RS232 OR IP CodeThe Auto start functionThe Display FunctionsTouch screen functionsThe step functionThe RGB functionThe tunable white functionAstro clock function for Astronomic based actionsCommunicationConnecting your PC with the central unitConnection trouble shootingCommunication with the DOIP central unitOverview of your domotic projectDiagnosticsRelaysDimmersMotorsDigital InputsAnalogue InputsAudio ZonesOther FunctionsInterfacesMonitorCARDSOFT – PORTASteps to set up CARDSOFT-PORTAAccess control options in PROSOFTAdd Proximity readersCreate Users and GroupsDefine ‘Access rights’Access management on users and groupsSchedule E-mail reports with TIMESOFT (or a function)TIMESOFTActions based on time programsDefining a clock actionGUISOFTPersonalised graphical controlGlossarySystem RequirementsSchematic ConfigurationsGUISOFT LicenceMaking a GUIRequirements Session workflowCREATING A GUIGUI SelectionGUI PropertiesGUISOFT ScreenAdding items to the GUICreating a iSGUIStart with the GUISOFTATMOS - iSGUI SelectionATMOS FeaturesGUISOFT Screen (ATMOS - iSGUI)Adding items to the iSGUI and ATMOSCreating a Control TowerTerminologyWorkflowDefine Functions to monitor and controlCreate an initial PROSOFT fileCreate a Control Tower configurationEvent logs (alarms)Get the GUI ready for useVideo door phone, Intercom on GUI and MAIOR Video door phone on GUI (TDS12052 and TDS12053 only)AV-SOFTAudio-IP software licenceMulti-Room Multi-SourceMulti-room/Multi-source: the differencesPhase 1: Choose the wanted audio-video configurationPhase 2: Assigning the RS232 Port and the IR flashersPhase 3: Configuring the Universal RS232 AV or IP interfacePhase 4: Configuring the audio buttons of the domotics installationEdit libraryAdd and edit devices into the libraryRecord IR codesPaste IR codesRS232, IPPolling codesSpecial codesBACK-UP the AV-SOFT LibraryConnection to the RS232 UNIVERSAL AV INTERFACERS232 connectionSplitter Cable for audio systemDALISOFTVOICESOFTAmazon Alexa Voice CotrolConfiguration of Amazon Alexa Voice ControlGoogle Home Voice ControlConfiguration of Google Home Voice ControlApplication examples and technical casesHow to integrate IP camera’s with TDSHow to integrate streaming audio devicesHEOS integrationSonos integrationBose integrationHow to integrate a heating and cooling systemHow to integrate a light sensorHow to setup an access control systemConfiguring a NUVO installation with three RS interfacesB&O IntegrationImplementing NuVo with Audio IP License (TDS15240)Configuring Audio Systems With the Audio IP License TDS15240Program a TCP client for third party system on port 23Night coolingMultiple DoIP Central UnitsEnergy managementTTecommThe TTecomm platformTSF Services HandbookThe ATMOS TSF SubscriptionQ&A Questions and AnswersHow to integrate a Daikin unit with standard ON-OFF controlHow to detect whether your Power Supply load is 70%What is full galvanic isolationCan you use one AUTOBUS power supply for AUTOBUS 1 AND 2 in a NANOS installationHow can you know that there is a voltage drop on AUTOBUS cableWhat is AUTOBUS terminator and how does it workMultiple installations TTcloud account policyCalculate the power loss and heat generation of an electrical distribution boardOn iSGUI, I keep getting an hourglass on some items TELETASK Technical handbook